MS-890 Industrial Automation Scanner
User Manual
9-3
Calibration
Calibration Steps
Follow this procedure for all three methods of calibration:
1. Position your symbol at the distance used in your application and confirm that it is at a
distance within the specifications for that symbol size (see
Position Scanner and
Symbol
on page 1-5).
2. If you are not certain of the code type, enable all code types by sending a
<P>
command
from the terminal window, or clicking on the
Autodiscrimination
button in
Calibration/
Advanced
in
ESP
.
3. Start the calibration procedure.
Note:
Once a successful calibration is completed, you may want to save the setting to
the calibration database (see
Configuration Database
on page 9-6).
4. Repeat calibration at other ranges and/or
symbol types you might be scanning in
your application.
5.
Check your readings at each end of the
scan width required for your application,
keeping
in mind that the scan width testing
may not produce results that are entirely
symmetrical.
Note:
If you are setting up for laser framing,
be sure that you only test for calibration in
the active areas of the scan beam.
6. To save the new settings (including focus,
gain, and tracking) for power-on, use the
Send/Recv
button or send a
<Zp>
command.
See
Configuration Database
on page 9-6 to learn how to setup a database using
calibration or manually specified values.
See
Advanced Calibration Features
on page 9-14 for ways to speed up and
improve your calibration process.
Note:
To silence the beeper, send
<K702,0>
or remove or block the test symbol.
Summary of Contents for MS-890
Page 1: ...MS 890 Industrial Automation Scanner User Manual P N 84 000890 Rev B...
Page 12: ...xii MS 890 Industrial Automation Scanner User Manual Statement of RoHS Compliance...
Page 26: ...1 14 MS 890 Industrial Automation Scanner User Manual Save Configuration in ESP...
Page 44: ...2 18 MS 890 Industrial Automation Scanner User Manual Send Receive Options...
Page 94: ...4 24 MS 890 Industrial Automation Scanner User Manual Tracking Adjustment...
Page 122: ...5 28 MS 890 Industrial Automation Scanner User Manual Autodiscriminate...
Page 154: ...6 32 MS 890 Industrial Automation Scanner User Manual Quality Output...
Page 168: ...7 14 MS 890 Industrial Automation Scanner User Manual Mismatch Replace...
Page 202: ...9 22 MS 890 Industrial Automation Scanner User Manual Calibration by Embedded Menu...
Page 212: ...10 10 MS 890 Industrial Automation Scanner User Manual Raster Laser by Embedded Menu...
Page 240: ...12 22 MS 890 Industrial Automation Scanner User Manual Scanner Status Requests...
Page 264: ...14 10 MS 890 Industrial Automation Scanner User Manual Mounting Plate...
Page 308: ...A 44 MS 890 Industrial Automation Scanner User Manual Glossary of Terms...