136 Specifications
_______________________________________________________________________________________________
________________________________________________________________________________________________
MICROPLEX
Operator’s Manual SOLID 166E
Edition 1.1
Mains connection:
400 V, 50Hz/60Hz
three-phase alternating current
(Europe, United Kingdom e.g.)
220 V +10%
50 to 60 Hz three—phase alternating current
(North America)
The SOLID 166E print system comes with a second power cable
(separate power supply for the touch panel; Europe: 230V)
Power admission:
maximum
permissible system
impedance Z
max
:
Apparent power max. 9.0 kVA
Use 32A fuses (40A, if necessary) for the mains connection
to enable the higher starting currents.
for Europe, United Kingdom e.g.:
P
st
= 3.2; d(t) > 3.30 % = 0.00 msec; d
max
= 2.25 %
RA = 0.041 Ohm + j0.026 Ohm
RN = 0.027 Ohm + j0.017 Ohm
Stacker:
Size:
Weight:
Paper accumulable
capacity:
Table lifting drive
system:
Paper sizes:
Paper set up
standard:
880 mm (H) x 600
mm (W) x
665
mm (D in print direction)
about 70 kg
265mm±5mm
Upward movement is by hands and
downward movement is by motors
Fanfold paper:
7
”
(17.8 cm) up to 14
”
(35.6 cm) length
7
”
(17.8 cm) up to 18
”
(45.7 cm) width
The first page is set with mountain fold.
(The first fold line is a mountain fold.)