Page 10
Functional Principle, Technical Data
optoCONTROL CLS1000
2.3.2
CLS1000-AI
Model
CLS1000-
AI-NPN
CLS1000-
AI-PNP
CLS1000-
AI-PP
CLS1000-
AI-NPN-T
CLS1000-
AI-PNP-T
CLS1000-
AI-PP-T
Operating range
max. 2000 mm (depending on transmission sensor)
Detection range
max. 1200 mm (depending on reflex sensor)
Response time
100 µs
Switching frequency
2.5 kHz (depending on pulse/pause ratio)
Frequency response (-3 dB)
10 kHz
Temperature stability
≤ 0.1 % FSO / K
Light source
infrared LED 870 nm
Permissible ambient light
50,000 lx
Supply voltage
1
12 … 30 VDC
Max. current consumption
50 mA
Analog output
Switchable 0 … 20 mA or 4 … 20 mA
Switching output
NPN
PNP
PP
NPN
PNP
PP
Switching
light/dark switching (switchable)
Signal input
-
Trigger in
Connection
Optical
FA socket M18x1 for screwable optical fiber (length 0.3 m ... 15 m, min. bending radius
18 mm)
Electrical
4-pin M12 socket for power supply and
signals (connection cable see accesso-
ries)
5-pin M12 socket for power supply and
signals (connection cable see accesso-
ries)
Mounting
DIN rail, DIN rail mounting (see accessories), mounting holes
Temperature
range
Storage
-10 ... +70 °C (+14 ... +158 °F)
Operation
-5 ... +55 °C (+23 ... +131 °F)
Shock (DIN EN 60068-2-27)
20 g / 11 ms in 3 axes, two directions and 1000 shocks each
Vibration (DIN EN 60068-2-6)
15 g / 10 … 1000 Hz in 3 axes, 10 cycles each
Protection class (DIN EN
60529)
IP67
Material
Plastic housing (polycarbonate)
Weight
200 g
Compatibility
with all CFS sensors (FAR, FAD, FAZ and FAS)
Control and display elements
Parameterization/operation via membrane keypad and OLED display on controller;
LED for power on
Special features
up to 9 teach-in modes;
adjustable switching output functions
on-delayed and off-delayed as well as
pulse output;
adjustable hysteresis 2 ... 25 %;
up to 9 teach-in modes;
adjustable switching output functions
on-delayed and off-delayed as well as
pulse output;
adjustable hysteresis 2 ... 25 %; many
trigger types
FSO = Full Scale Output
The specified data apply for a consistent room temperature of 22 °C, sensor is continuously in operation, open signal
outputs.
1) Residual ripple ≤ 10%