Page 31
Operation
optoCONTROL CLS1000
5.3
Overview of Operating Menu
Autom. spread
SPRD
AUTO
Manual spread
SPRD
MAN
Meas. operation
Threshold
Meas. value
Teach-In
MENU
T
Standard
T
ST
1
1
0
0
Values:
ST
AD value
1
1
1
0
Standard display
HighSensitive
T
HST
1
2
0
0
Values:
ST
AD value
1
2
1
0
LowSensitive
T
LST
1
3
0
0
LST
AD value
1
3
1
0
Dark
T
DT
1
4
0
0
DT
AD value
1
4
1
0
OptimalBright
T
OBT
1
5
0
0
OBT
AD value
1
5
1
0
OptimalDark
T
ODT
1
6
0
0
ODT
1
6
1
0
PeaktoPeak
T
PPT
1
7
0
0
PPT
1
7
1
0
2-Point
T
2PT
1
8
0
0
PT-1
1
8
1
0
ManualSensitive
T
MST
1
9
0
0
M-xx
1
9
1
0
AD value
AD value
AD value
PT-2
1
8
2
0
AD value
Values:
Values:
Values:
Values:
Values:
Values:
Values:
Values::
AD value
AD-Wert
1
9
2
0
Values::
100 ...
4000 [Bit]
Switching
threshold
Config AO
MENU
Config Sensor
MENU
Info Sensor
MENU
Factory settings
MENU
Exit (Lock)
MENU
Switching polarity
Q1
OPM
Output type
Q1
TYPE
Hysteresis
Q1
HYS
Q1
TRH
Timer
Q1
TIME
ANA
SEN
Trigger type
SEN
TRG
5
0
0
0
TRG
5
1
0
0
Values:
Value
-OFF: No ext. trigger
-POS: Rising edge
-NEG: Falling edge
-HIGH: Int. trigger with High
-LOW: Int. trigger with Low
Config Q1
MENU
Q1
ANA
TYPE
Spread
ANA
SPRD
4
0
0
0
INFO
RST
EXIT
Preset
INFO
PRST
6
0
0
0
Values:
PRST
Value
Firmware
FW
Value
6
1
0
0
6
2
0
0
7
0
0
0
8
0
0
0
Firmware
INFO
FW
Confirmation
RST
NO
Confirmation
RST
YES
Confirmation
EXIT
NO
EXIT
YES
TYPE
4
1
0
0
Values: - 0-20: Current output
0 ... 20 mA
- 4-20:
Current output
4 ... 20 mA
Value
Set spread
SPRD
SET
4
2
0
0
4
2
2
0
4
2
3
0
Offset
MAN
OFFS
Factor
MAN
GAIN
Spread point 1
AUTO
SP1
Spread point 2
EXIT
SP2
SET
4
2
1
0
Values:
- OFF:
Spread disabled
- ON:
Spread enabled
Value
OFFS
4
2
1
0
Values:
0 ... 4095 [Bit]
Value
GAIN
4
2
2
2
Values:
Value
4
2
3
1
4
2
3
2
OPM
2
1
0
0
Values:
- L-SW:
Light switching
-
D-SW: Dark switching
Value
TYPE
2
2
0
0
Values:
Value
- PP: PushPull
- PNP: PNP-Type
- NPN: NPN-Type
HYS
2
3
0
0
Values:
Value
2 ... 25 [%]
TRH
2
4
0
0
Values:
Value
100 ... 4000 [Bit]
2
0
0
0
Timer type
TIME
TYPE
Timer-Wert
TIME
VAL
2
5
0
0
TYPE
2
5
1
0
Values:
Value
VAL
2
5
2
0
Values:
Value
1... 9999 [ms]
- OFF: No timer
- OND: On-delayed
- OFFD: Off-delayed
- IMP: Pulse output
+- 0,1 ... 10,0
Standard display
Standard display
Standard display
Standard display
Standard display
Standard display
Standard display
Standard display
Standard display
Output type
1
2
0
0
0
0
1)
Output type
menu only available for CLS1000-AI
2)
Config. sensor
menu with
trigger type
only
available for controller with trigger function
Standard display
2 sec.
Legend
Menu Structure
TRG
5
1
0
0
Values:
Value
-OFF: ...
-POS: ...
-HIGH: ...
-LOW: ...
PT-2
1
8
2
0
AD value
Values:
OFFS
4
2
1
0
Values:
0 ...
4095[ms]
Value
Teach-In
MENU
T
0
0
0
0
Value selection
Set / apply value
Set high values
Menu structure
xx =
Amplification
level
Confirmation
Reset parameters
to factory settings
Standard display
SP-1
Meas. value
Values:
SP1
Values:
Value
0 ... 4095 [Bit]
SP-1
Value SP1
Values:
SP1 = 0
Yes
No
Up /
DOWN
Up /
DOWN
SET
SET
SET
ESC
ESC
Back to
4230
without value storage
Back to
4230
with value storage
Spread point 1
SP-2
Meas. value
Values:
SP2
Values:
Value
0 ... 4095 [Bit]
SP-2
Value SP1
Values:
SP2 = 0
Yes
No
Up /
DOWN
Up /
DOWN
SET
SET
SET
ESC
ESC
Back to
4230
without value storage
Back to
4230
with value storage
Spread point 2
Switching threshold