Page 44
Operation
optoCONTROL CLS1000
Function
Description
Menu
Switching output
The switching output is set according to the switching threshold.
This depends on the
T
(Teach-in) menu
The switching outputs can be individually configured, provided they do not
mutually influence on one another. Parameterization/operation via membrane
keyboard and Operating menu
PP (Push-Pull), PNP, NPN
T
Switching polarity SP
Light switching
and
Dark switching
Parameterization/operation via membrane keyboard and Operating menu
; indicated via display on controller.
Q1
>
OPM
Switching threshold
1 ... 99 % light intensity; corresponds to 100 ... 4000 bits; 80 % = 3200 bits;
hysteresis 2 ... 25 %; 5 %
T
Q1
Signal spread/ Mea-
surement value
spread
Analog spread of the analog output. It is possible to scale an important signal
range to the entire analog range.
Parameterization/operation via membrane keyboard and Operating menu
indicated via display on controller..
ANA
>
SPRD
Teach functions
Parameterization/operation via membrane keyboard and Operating menu
indicated via display on controller.
T
Triggering
The sensor can be triggered via Pin 5 in the trigger versions.
Operation via membrane keyboard and Operating menu
;
indicated via display on controller.
SEN
>
TRG
WatchDog
Restart in case of error. In the event of a controller error, the controller restarts
(Error recovery).
-