Page 43
Operation
optoCONTROL CLS1000
5.5
Functions
Function
Description
Menu
Dark switching
The
dark switching
function means that the given output is activated
(carries current) when no light hits the receiver; this corresponds to the opener
function (N.C.). The switching output of a photoelectric device is activated (e.g.
output relay is operated) when no light hits the light receiver. If the light receiv-
er is not illuminated in dark switching, the switching output is activated and the
output relay is operated. The relay drops when the light receiver is illuminated.
Parameterization/operation via membrane keyboard and Operating menu
indicated via display on controller.
Q1
>
OPM
Intensity display
Intensity display via display; parameterization and operation via membrane
keyboard and Operating menu
indicated via display on controller.
The light received at the receiver diode is output on the display as an intensity
value depending on the amplifier level and is also output at the analog output,
depending on the version.
Inverting the
analog output
The analog signal can be inverted. Reverse scaling
Parameterization/operation via membrane keyboard and Operating menu
; indicated via display on controller.
INA
Ambient light/
pulsed light
Ambient light can disrupt the effectiveness of an optical system. The receiver
cannot differentiate whether the light it is receiving originates from the associ-
ated transmitter or from another source (e.g. the sun). To minimize this influ-
ence, the light emitted by the transmitter is pulsed at a certain frequency. The
receiver only takes into account the portion of received light that has the same
frequency. The effect of all other light (ambient light) is suppressed.
The respectively applicable permissible ambient light can be found in the Tech-
nical Data
i
This function cannot be switched off.
-
Light switching
The
l
ight switching
function means that the given output is activated (car-
ries current) when light hits the receiver; this corresponds to the closer func-
tion (N.O.). If a photoelectric device is set to the
l
ight switching
function,
the switching output is activated (e.g. a relay is operated) when light hits the
receiver. In one-way and reflection light barriers, this is the case when the light
path is free, and for light scanners, when something to be sensed is present.
If the light receiver is illuminated in light switching, this means the controller is
active and the output relay is operated. The relay drops when the light path is
interrupted.
Parameterization/operation via membrane keyboard and Operating menu
; indicated via display on controller.
Q1
>
OPM
Averaging
Sliding; 1 (= OFF) / 2 / 5 / 10 / 20 / 50 / 75 / 100 / 200 / 500 / 1000 / 2000 [val-
ues]
Parameterization/operation via membrane keyboard and Operating menu
; indicated via display on controller.
SEN > AVG
Parameterization
Parameterization is done via the membrane keyboard and Operating menu
; indicated via display on controller..
All menus