Page 40
Operation
optoCONTROL CLS1000
Create your testing/measurement situation and note the displayed measurement values.
Apply the current measurement value as
SP1
by pressing the
set
key.
The values from SP1 must be confirmed but can still be adjusted.
Set the thousands position with
. Confirm with the
set
key.
Set the hundreds position with
. Confirm with the
set
key.
Set the tens position with
. Confirm with the
set
key.
Set the ones position with
. Confirm with the
set
key.
The set value is applied as
SP1
, the factor is determined. An offset is not necessary at this point in time because the
value 0 is applied for
SP2
(Spread point 2).
If you only need one spread point (teach point), the automatic spread is finished.
Press the
esc
key multiple times to return to the standard view.
If you require 2 spread points (teach points), press the
keys to navigate to the menu item
SP2
(Spread point
2).
If a spread point
SP2
is present, it is displayed. You can switch to the current measurement value display by pressing the
keys.
If no
SP2
is available yet, the current measurement value is displayed and simultaneously the 3 bars at the top flash to
indicate that the displayed value is the current measurement value.
Procedure for Spread point 2:
SP-2
Meas. value
Values:
SP2
Values:
Value
0 ... 4095 [Bit]
SP-2
Value SP1
Values:
SP2 = 0
Yes
No
Up /
DOWN
Up /
DOWN
SET
SET
SET
ESC
ESC
Back to
4230
without value storage
Back to
4230
with value storage
Spread point 2
Fig. 38 ANA / Config AO / SPRD - Spread point 2 menu
Create your testing/measurement situation and note the displayed measurement values.
Apply the current measurement value as
SP2
by pressing the
set
key.
The values from
SP2
must be confirmed but can still be adjusted.
Set the thousands position with
. Confirm with the
set
key.
Set the hundreds position with
. Confirm with the
set
key.
Set the tens position with
. Confirm with the
set
key.
Set the ones position with
. Confirm with the
set
key.
The set value is applied as
SP2
, the factor is determined.
If you need 2 spread points, the automatic spread is finished.
Press the
esc
key multiple times to return to the standard view.