Revision 8.6
SECTION 4 : INSTALLATION
58
MECHANICAL
SIZE
MOUNTING HOLE ARRANGEMENT (measurement in mm)
M2000
1200
– 2000A
Thyromat
4.2.5.
Mounting Procedure
Identify a suitable mounting surface.
Clean the mounting surfaces and make sure that they are free of any oil or grease.
Mark the mounting holes in accordance with the applicable instructions and dimensions
identified in paragraphs 4.2.2. (Mounting Instructions) and 4.2.4. (Mounting
Arrangements).
Use the spirit level to ensure that the unit will be mounted level.
Using the hammer and centre punch, punch the applicable centres for the mounting holes.
Using the electric drill and applicable drill bit, drill the mounting holes, take care not to
damage any objects and / or equipment that may be mounted on the opposite side of the
mounting surface.
Make sure that the mounting surfaces around the holes are stripped of paint and free of any
grease or oil so that a good earth can be obtained.
With the aid of an assistant, lift the THYROMAT into position.
Insert the fasteners provided and secure the THYROMAT to the mounting surface using the
applicable tools. Where bolts are used to mount the THYROMAT, make sure that they are
torqued down to the correct values (refer to table 4-3 Mounting Fastener Torque Values).
Clean up the immediate area of all iron filings and / or metal shavings.
Remove all tools and / or materials used in the mounting process.