Revision 8.6
SECTION 3 : TRAVEL PARAMETERS
40
3.3.
TRAVEL APPLICATION PARAMETERS LIST
Table 3-2 lists the typical parameter settings for Travel Software Version CTT01.XX applications.
Table 3-2 : Travel Parameter List
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
1
CT Ratio
CT ratio
50:1 to 3000:1
-
50:1
2
CT Enable
Enable CTs
Yes or No
-
Yes
3
Motor Current
Motor full load current
< 60% of CT ratio
-
10
4
Overload class
Overload class type
5 or 10
-
5
5
Notch 1
Notch 1 speed
4% to 20%
1
10%
6
Notch 2
Notch 2 speed
5% to 40%
1
20%
7
Notch 3
Notch 3 speed
5% to 60%
1
30%
8
Notch Plugging
Notch plugging
Yes or No
1
Yes
9
Notch Plugging V
Notch plugging voltage
0% to 90%
5%
40%
10
Neutral PlugginV
Neutral plugging Voltage
0% to 90%
5%
70%
11
Neutral Decel P
Neutral Deceleration Profile
2 to
– 20 sec
1sec
5 sec
12
Brake Plugging V
Voltage to apply when plugging
in the opposite direction
50% to 90%
5%
70%
13
Brakes ON Speed
Brakes Application Speed
2% to 10%
1
4%
14
Max Stall V
Maximum Stall Voltage
20% to 80%
5%
70%
15
Minimum Start V
Minimum Start Voltage
10% - 80%
5%
30%
16
N123 Accel
Acceleration time between slow
speed Notches
5 to 20 sec
1
5 sec
17
N4 Accel Profile
Acceleration rate for full speed
acceleration
2 to 20 sec
1 sec
5 sec
18
Ph Shift Off Tim
Phase shifter off time delay
60 to 240 ms
20 ms
100 ms
19
Notch 4 Delay
Notch 4 delayed time
0 to 5 sec
1 sec
0 sec
20
Sep Dir Signals
Separate directional signals
Yes or No
-
No
21
Plug Reduced
%sp
Plug Reduced %speed
0% to 20%
5%
15%
22
N123 smooth Prfl
N123 smoothness Profile
10 - 300
10
160