U
U
s
s
e
e
r
r
M
M
a
a
n
n
u
u
a
a
l
l
Revision 8.6
SECTION 3 : HOIST PARAMETERS
29
SECTION 3 : PARAMETERS BDC-H
3.1.
HOIST APPLICATION PARAMETERS LIST
Table 3-1 lists the typical parameter settings for BDC-H Hoist Software Version 11.XX applications.
Table 3-1: Hoist Parameter List for BDC-H Applications
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
1
CT ratio
Current transformers ratio
50:1 to 3000:1
-
50:1A
2
Motor current
Motor nominal current
< 60% of CT ratio
Minimum 2A
10A
3
Overload class
Thermal overload class type
5 or 10
-
5
4
Notch 1
First Notch Speed
5% to 20%
1%
10%
5
Notch 2
Second Notch Speed
5% to 40%
1%
20%
6
Notch 3
Third Notch Speed
5% to 50%
1%
30%
7
Hoist plugging
Enable Hoist plugging
Yes or No
-
No
8
Hoist plugging V
Hoist plugging % voltage
20% to 80%
5%
50%
9
Lower plugging V
Lower plugging % voltage
50% to 100%
5%
80%
10
Brake release I
Brake releasing current
0% to 50%
5%
15%
11
Hoist Start Volt
Hoisting minimum start volts
30% to 80%
1%
60%
12
Stop Delay
Torque hold delay at stop
300
– 1500 ms
50 ms
600 ms
13
Lower plugg out
Lower plugging time out
2000
– 5000 ms
250 ms
3000 ms
14
Max Stall V
Maximum stall voltage
70% to 100%
5%
80%
15
Ph Shift On Time
Phase shifter on time delay
0 to 140 ms
20 ms
0 ms
16
Ph Shift Off Tim
Phase shifter off time delay
60 to 240 ms
20 ms
100 ms
17
Sep Dir Signals
Separate directional signals
Yes or No
-
No
18
Load defaults
Load default parameters
Yes or No
-
No
NOTE:
All Hoist Control software versions 11.XX must be used with Control Panel software