SECTION 3 : TRAVEL PARAMETERS
43
3.4.5.
Notch Speed 1
3.4.6.
Notch Speed 2
3.4.7.
Notch Speed 3
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
5
Notch 1
Notch 1 speed
4% to 20%
1
10%
6
Notch 2
Notch 2 speed
5% to 40%
1
20%
7
Notch 3
Notch 3 speed
5% to 60%
1
30%
These three parameters set the intermediate slow speeds.
CAUTION
WHERE SPEEDS IN EXCESS OF 30% ARE
SELECTED SPECIAL ROTOR RESISTANCE
DESIGN MAY BE NECESSARY.
CONSULT YOUR LOCAL MH AUTOMATION
REPRESENTATIVE FOR ASSISTANCE.
3.4.8
Notch Plugging
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
8
Notch Plugging
Notch plugging
Yes or No
-
Yes
This parameter enables or disables plugging between Notches.
Refer to Parameter 9 below for further details.
3.4.9
Notch Plugging Voltage
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
9
Notch Plugging V
Notch plugging voltage
0% to 90%
5%
40%
This parameter sets the Notch plugging voltage for both directions.
Notch plugging when activated, makes use of dynamic reverse plugging, to retard the Travel motion to
the required speed, the magnitude of the plugging torque is proportional to the square of the plugging
voltage applied, therefore the voltage setting will have an effect on the smoothness of the motion
operation.