27
2
INSTALLATION AND WIRING
3) Source logic type
•
In this logic, a signal switches on when a current flows into the corresponding signal
input terminal.
Terminal PC is common to the contact input signals. Terminal SE is common to the
open collector output signals.
•
When using an external power supply for transistor output, use terminal SD as a
common to prevent misoperation caused by undesirable current.
(5) How to use the STOP signal
The following connection example shows how to self-hold the start signals (forward
rotation, reverse rotation).
Use Pr. 180 to Pr. 183 (input terminal function selection) to assign the STOP signal.
Current
STF
STR
PC
R
R
AX80
24VDC
RUN
SE
1
9
R
Inverter
R
AY-80 type
transistor output
module.
9
1
2
10
PC
STF
STR
SD
24VDC
(SD)
24VDC
Inverter
Current flow
RL
(STOP)
MRS
RES
SD
STF
STR
Stop
Forward
rotation
Reverse
rotation
(Wiring example for sink logic)
M4500E.book 27 ページ 2005年2月22日 火曜日 午後5時7分