62
PARAMETERS
P
ara
me
te
r L
is
t
4.1 Parameter List
4.1.1
Parameter list
Func-
tion
Param-
eter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Custo-
mer
Setting
Basi
c fu
n
c
ti
o
n
s
0
Torque boost (Note 1)
0 to 30%
0.1%
4%/3%
(Note 4)
71
1
Maximum frequency
0 to 120Hz
0.01Hz
(Note 3)
120Hz
72
2
Minimum frequency
0 to 120Hz
0.01Hz
(Note 3)
0Hz
72
3
Base frequency (Note 1)
0 to 400Hz
0.01Hz
(Note 3)
60Hz
73
4
Multi-speed setting
(high speed)
0 to 400Hz
0.01Hz
(Note 3)
60Hz
74
5
Multi-speed setting
(middle speed)
0 to 400Hz
0.01Hz
(Note 3)
30Hz
74
6
Multi-speed setting
(low speed)
0 to 400Hz
0.01Hz
(Note 3)
10Hz
74
7
Acceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s/10s
(Note 4)
75
8
Deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s/10s
(Note 4)
75
9
Electronic thermal O/L
relay
0 to 500A
0.01A
Rated
output
current
(Note 5)
77
S
ta
n
da
rd
ope
ra
ti
o
n
f
u
nc
ti
on
s
10
DC injection brake
operation frequency
0 to 120Hz
0.01Hz
(Note 3)
3Hz
78
11
DC injection brake
operation time
0 to 10 s
0.1 s
0.5 s
78
12
DC injection brake voltage
0 to 30%
0.1%
2%
78
13
Starting frequency
0 to 60Hz
0.01Hz
0.5Hz
79
14
Load pattern selection
(Note 1)
0 to 3
1
0
80
15
Jog frequency
0 to 400Hz
0.01Hz
(Note 3)
5Hz
81
16
Jog acceleration/
deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/ 0.01 s
0.5 s
81
18
High-speed maximum
frequency
120 to
400Hz
0.01Hz
(Note 3)
120Hz
72
19
Base frequency voltage
(Note 1)
0 to 1000V,
8888, 9999
0.1V
9999
73
20
Acceleration/deceleration
reference frequency
1 to 400Hz
0.01Hz
(Note 3)
60Hz
75
21
Acceleration/deceleration
time increments
0, 1
1
0
75
22
Stall prevention operation
level
0 to 200%
0.1%
150%
82
23
Stall prevention operation
level compensation factor
at double speed
(Note 6)
0 to 200%,
9999
0.1%
9999
82
M4500E.book 62 ページ 2005年2月22日 火曜日 午後5時7分
Summary of Contents for M4000E series
Page 11: ...MEMO ...
Page 23: ...12 MEMO ...
Page 55: ...44 MEMO ...
Page 173: ...162 MEMO ...