125
4
PARAMETERS
(2) Communication operation presence/absence and data format types
Communication operation presence/absence and data format types are as follows:
* In the communication request data from the computer to the inverter, 10ms or more is
also required after "no data error (ACK)". (Refer to page 128.)
No.
Operation
Run
Command
Running
Frequency
Parameter
Write
Inverter
Reset
Monitoring Parameter
Read
1)
Communication request is
sent to the inverter in
accordance with the user
program in the computer.
A'
A
(A")
Note 1
A
(A")
Note 2
A
B
B
2) Inverter data processing
time
Present
Present
Present
Absent
Present
Present
3)
Reply data
from the
inverter
(Data 1) is
checked for
error.
No error*
(Request
accepted)
C
C
C
Absent
E,E'
(E")
Note 1
E
(E")
Note 2
With error
(request
rejected)
D
D
D
Absent
F
F
4) Computer processing delay
time
Absent
Absent
Absent
Absent
Absent
Absent
5)
Answer from
computer in
response to
reply data 3).
(Data 3) is
checked for
error)
No error*
(No inverter
processing)
Absent
Absent
Absent
Absent
G
G
With error.
(Inverter
outputs 3)
again)
Absent
Absent
Absent
Absent
H
H
Note: 1. Setting any of "0.01 to 9998" in Pr. 37 "speed display" and "1" in instruction
code "HFF" changes the data format to A" or E". The output frequency is the
value of the speed display and its unit is 0.001r/min. If the instruction code FF
is not 1, the unit is 1r/min and the 4-digit data format can be used.
2. The read/write data format of Pr. 37 "speed display" is always E"/A".
M4500E.book 125 ページ 2005年2月22日 火曜日 午後5時7分