145
4
PARAMETERS
4.2.40 User group selection (Pr. 160, Pr. 173 to Pr. 176)
Pr. 160 "user group read selection"
Pr. 173 "user group 1 registration"
Pr. 174 "user group 1 deletion"
Pr. 175 "user group 2 registration"
Pr. 176 "user group 2 deletion"
Among all parameters, a total of 32 parameters can be registered to two different user
groups. The registered parameters may only be accessed.
The other parameters cannot be read.
CAUTION
The zero current detection level setting should not be too high, and the
zero current detection time setting should not be too long. Otherwise, the
detection signal may not be output when torque is not generated at a low
output current.
To prevent the machine and equipment from resulting in hazardous
conditions by use of the zero current detection signal, install a safety
backup such as an emergency brake.
Pr. 156
Refer to Pr. 22.
Pr. 158
Refer to Pr. 52.
Parameter
Number
Factory
Setting
Setting Range
Remarks
160
0
0, 1, 10, 11
173
0
0 to 999
174
0
0 to 999, 9999
9999: Batch deletion
175
0
0 to 999
176
0
0 to 999, 9999
9999: Batch deletion