9
1
OUTLINE
1.3.5
Reinstallation and removal of the operation panel
To ensure safety, reinstall and remove the option operation panel (FR-PA02
-
02
) after
switching power off.
The charging area and control printed board are exposed on the rear surface of the
operation panel. When removing the operation panel, always fit the rear cover option FR-
E5P. Never touch the control printed board because touching it can cause the inverter to fail.
Reinstallation
Insert the mounting hook (left hand side) of the operation panel into the mounting
position of the inverter and push in the right hand side mounting catch to install the
operation panel.
Removal of the operation panel
Hold down the portion A indicated by the arrow and lift the right hand side using
the portion B indicated by the arrow as a support, and pull out the operation panel
to the right.
(If the above procedure is not used for removal, the internal connector may be
damaged by the force applied.)
FR-PA02-
02
Mounting position
Hook
A
1)
2)
3)
1)
A
B
2)
3)
M4500E.book 9 ページ 2005年2月22日 火曜日 午後5時7分
Summary of Contents for M4000E series
Page 11: ...MEMO ...
Page 23: ...12 MEMO ...
Page 55: ...44 MEMO ...
Page 173: ...162 MEMO ...
Page 199: ...188 MEMO ...