172
PROTECTIVE FUNCTIONS
Operation Panel Indication
oL
FR-PU04-MGI
oL
Name
Stall prevention (overvoltage)
Description
During
deceleration
If the regenerative energy of the motor
increases too much to exceed the brake
capability, this function stops the decrease in
frequency to prevent overvoltage shut-off. As
soon as the regenerative energy has reduced,
deceleration resumes.
Check point
Check for sudden speed reduction.
Corrective action
The deceleration time may change. Increase the deceleration
time using Pr. 8 "deceleration time".
Operation Panel Indication
PS
FR-PU04-MGI
PS
Name
PU stop
Description
A stop made by pressing the
key of the PU has been set
in Pr. 75 "PU stop selection".
Check point
Check for a stop made by pressing the
key of the
operation panel during external operation.
Corrective action
Refer to page 108.
Operation Panel Indication
Err.
Description
This alarm appears if:
•
The RES signal is on;
•
You attempted to set any parameter value in the external
operation mode;
•
You attempted to change the operation mode during
operation;
•
You attempted to set any parameter value outside its setting
range.
•
You attempted to set any parameter value during operation
(while signal STF or STR is ON).
•
You attempted to set any parameter value while parameter
write is being inhibited in Pr. 77 "parameter write disable
selection".
Corrective action
Perform operation correctly.
STOP
RESET
STOP
RESET