SECTION 2 - GENERAL INSTALLATION INFORMATION
2-8
MP SERIES CONE CRUSHER TECHNICAL REFERENCE MANUAL
Table 2-3 MP1000 Clearance Dimensions (refer to Figure 2-4)
Callout
Description
Standard
mm (in.)
Short Head
mm (in.)
A
Main frame flange
1950
(6' 4-3/4")
1950
(6' 4-3/4")
B
Main frame flange
2000
(6' 6-3/4")
2000
(6' 6-3/4")
C
Main frame flange
1950
(6' 4-3/4")
1950
(6' 4-3/4")
D
Main frame hub diameter
975
(3' 2-3/8")
975
(3' 2-3/8")
E
To bottom of main frame hub
310
(1' 0-3/16")
310
(1' 0-3/16")
F
To bottom of oil piping
670
(2' 2-3/8")
670
(2' 2-3/8")
G
To top of turning brackets
3660
(12' 0-1/8")
3660
(12' 0-1/8")
H
Adjustment ring maximum diameter
5360
(17' 7")
5360
(17' 7")
J
Clearance required for removing countershaft assembly
4320
(14' 2-1/16")
4320
(14' 2-1/16")
K
To end of countershaft
2855
(9' 4-3/8")
2855
(9' 4-3/8")
L
Maximum height to top of feed hopper
3926
(12' 10-9/16")
3993
(13' 1-3/16")
M
Inside diameter of feed hopper
2530
(8' 3-5/8")
2490
(8' 2-1/16")
N
To top of feed plate
3026
(9' 11-1/8")
2935
(9' 7-9/16")
O
Overall height of bowl assembly
2186
(7' 2-1/16")
2180
(7' 1-13/16")
P
Adjustment cap maximum diameter
3550
(11' 7-3/4")
3550
(11' 7-3/4")
Q
Clearance required for removing bowl assembly
5896
(19' 4-1/8")
5890
(19' 3-7/8")
R
Overall height of head assembly
2323
(7' 7-1/2")
2127
(6' 11-3/4")
S
Head or mantle maximum diameter
2392
(7' 10-3/16")
2369
(7' 9-1/4")
T
Clearance required for removing head assembly
6033
(19' 9-1/2")
5837
(19' 1-13/16")
U
Tramp release side to side
4610
(15' 1-1/2")
4610
(15' 1-1/2")
V
Additional upward travel due to clearing stroke
150
(5-15/16")
150
(5-15/16")
Summary of Contents for MP1000
Page 1: ...Nordberg MP Series Cone Crusher ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 64: ...SECTION 0 SAFETY 0 56 MP SERIES CONE CRUSHER TECHNICAL REFERENCE MANUAL ...
Page 66: ......
Page 74: ......
Page 154: ...Countershaft and Countershaft Box Callout Description 1 Countershaft 2 Countershaft box 1 2 ...