CSP–900RFM206E–1
ROTORCRAFT FLIGHT MANUAL
MD900 With PW 206E
Normal Procedures
FAA Approved
Original
4–28
4–12.ENGINE/AIRCRAFT SHUTDOWN – NORMAL
NOTE
:
Shut down the engines before exiting the helicopter unless safety or operational
considerations dictate otherwise.
Maximum demonstrated wind speed for starting and stopping the rotor is 50
knots.
F
Collective stick
FULL DOWN; FRICTION ON
F
Cyclic stick
TRIM TO NEUTRAL
(REF FIGURE 4–9)
F
Pedals
NEUTRAL
F
Engine control panel
F
F
L ENGINE and R ENGINE
SET TO IDLE
F
All unnecessary electrical equipment
OFF
F
Utility panel:
F
F
Heat
OFF
F
F
AC (if installed)
OFF
F
F
IPS (if installed)
OFF
F
F
Pitot heat
OFF
F
Lighting control panel
AS DESIRED
F
Electrical master panel:
F
F
Avionics master switch
OFF
F
F
L GEN/R GEN switches
OFF
F
Fuel system panel:
F
F
L BOOST/R BOOST
OFF
F
Engine control panel:
F
F
L ENGINE and R ENGINE
OFF
F
ENG OUT indications
CHECK IIDS
Do not use collective pitch to slow rotor.
CAUTION