ELECTRICAL FIRE
Indications:
Smoke and fume accumulation in the cabin.
Conditions:
On ground
Procedures:
F
Engine control switches
OFF
F
Passengers/crew
EVACUATE
F
Rotor brake (if installed)
APPLY
F
Power switch
OFF
Conditions:
In flight
Procedures:
F
Cabin heat
OFF
F
Fresh air vents
OPEN
F
Generator switches
OFF
F
If smoke/fire conditions persist:
F
F
POWER switch
ESNTL
F
Land as soon as possible.
F
After landing:
F
F
Engine control switches
OFF
F
F
Rotor brake (if installed)
APPLY
F
F
Power switch
OFF
F
F
Passengers/crew
EVACUATE