CSP–900RFM206E–1
ROTORCRAFT FLIGHT MANUAL
MD900 With PW 206E
Limitations
FAA Approved
Original
2–6
2–7. ROTOR SPEED LIMITATIONS
Power on:
Continuous operation
Maximum 101%
Minimum 99%
Transient Range:
91% to 98%
102% to 108%
Power off:
Continuous operation:
108% maximum
88% minimum
2–8. TRANSMISSION LIMITATIONS
Maximum transmission oil pressure: 104% PSI
Minimum transmission oil pressure: See Figure 2−11
Maximum transmission oil temperature: 110
°
C
Minimum transmission oil temperature: −18
°
C
2–9. POWER PLANT LIMITATIONS
Any time a limit is exceeded, the exceeded limit shall be reported to maintenance
as soon as possible.
EGT and N
G
exceedances are cumulative in nature and must be
recorded in the engine log book.
Torque limits:
Normal:
Maximum continuous:
100%
Takeoff (5 minute):
101% to 110%
Maximum transient over torque: 111% to 124% for 10 seconds
OEI limits:
Maximum continuous: 124%
2.5 minute: 125% to 130%
Torque greater than 130%: NOT ALLOWED
CAUTION
Summary of Contents for MD900 with PW206E