62
1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
STEP 11 - CONNECT CHARGE LINES & BATTERIES
CONNECTING CHARGE LINE TO MASTER
DISCONNECT SWITCH
FIG. 62-2
3.
If
vehicle batteries
are used
to power the Liftgate, do the
following. At the pump box,
remove nut from
OUTPUT
terminal on master disconnect
switch
(FIG. 62-2)
. Connect
positive
(+)
power cable (charge
line) to
OUTPUT
terminal on
master disconnect switch
(FIG.
62-2)
. Reinstall and tighten nut.
1.
Remove nut from negative
(-)
battery terminal. Disconnect
negative
(-)
battery cable from
vehicle battery
(FIG. 62-1)
.
Start nut on the terminal.
Prevent injury and equipment damage. Before connecting charge lines or
power cables, ensure negative (-) battery cable is disconnected at vehicle bat-
tery or battery box (if equipped). Ensure master disconnect switch is turned
OFF on the pump box.
WARNING
!
NOTE:
Ensure batteries are fully charged before operating Liftgate & before deliv-
ery to customer.
POSITIVE (+)
BATTERY TERMINAL
NEGATIVE (-)
BATTERY CABLE
NEGATIVE (-)
BATTERY TERMINAL
NUT
POSITIVE (+)
POWER CABLE
CONNECTING CHARGE LINE TO BATTERY
FIG. 62-1
2.
Remove nut from positive
(+)
battery terminal. Connect
positive
(+)
power cable
(charge line) to positive
(+)
battery terminal
(FIG. 62-1)
.
Reinstall and tighten nut.
OUTPUT
CHARGE
LINE
MASTER DISCONNECT
SWITCH
CHARGE LINE
MASTER DISCONNECT
SWITCH
NOTE:
Skip instruction 3 below
if connecting to optional
battery box.
Summary of Contents for BMR-CS
Page 103: ......