101
1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
ELECTRICAL SYSTEM DIAGRAMS
MTE PUMP
BUCHER PUMP
Solenoid Switch:
• Coil: 5.4
Ω
@ 70ºF. ±15%
• Ampere: 2.2A @ 12V
• Coil terminal torque: 10-15
lb-in
• Contact terminal torque: 30-35
lb-in
Solenoid Switch:
• Coil: 5.4
Ω
@ 70ºF. ±15%
• Ampere: 2.2A @ 12V
• Coil terminal torque: 10-15
lb-in
• Contact terminal torque: 30-35
lb-in
Solenoid Valves (H, E, and C):
• Coil: 6.6
Ω
@ 70ºF. ±15%
• Ampere: 1.8A @ 12V
• Coil nut torque: 15-45
lb-in
Solenoid Valves (H, E, and C):
• Coil: 4.0
Ω
@ 70ºF. ±15%
• Ampere: 2.5A @ 10V
• Coil nut torque: 15-45
lb-in
Solenoid Valve (B):
• Coil: 7.5
Ω
@ 70ºF. ±15%
• Ampere: 1.6A @ 12V
• Coil nut torque: 15-45
lb-in
Solenoid Valve (B):
• Coil: 4.0
Ω
@ 70ºF. ±15%
• Ampere: 2.5A @ 10V
• Coil nut torque: 15-45
lb-in
H, E, C & B Valve Cartridge Torque
:
25-30
lb-ft
maximum
• Coil nut torque: 15-45
lb-in
H, E, C & B Valve Cartridge Torque
:
25-30
lb-ft
maximum
• Coil nut torque: 15-45
lb-in
Solenoid Valve (D):
• Coil: 8.0
Ω
@ 70ºF. ±15%
• Ampere: 1.5A @ 12V
• Coil nut torque: 3-4.5
lb-ft
• Valve cartridge torque: 18.5-22
lb-ft
Solenoid Valve (D):
• Coil: 8.0
Ω
@ 70ºF. ±15%
• Ampere: 1.5A @ 12V
• Coil nut torque: 3-4.5
lb-ft
• Valve cartridge torque: 18.5-22
lb-ft
Pump Selector Switch Terminal Stud
Torque:
140
lb-in
maximum
Pump Selector Switch Terminal Stud
Torque:
140
lb-in
maximum
Cable Ground Stud Torque
:
24
lb-ft
maximum
Cable Ground Stud Torque
:
24
lb-ft
maximum
BMR-CS ELECTRICAL & HYDRAULIC VALVES TORQUE VALUES
Summary of Contents for BMR-CS