58
1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
STEP 9 - GROUND PUMP TO VEHICLE FRAME
FIG. 58-1
GROUND
CABLE
PUMP
BOX
FIG. 58-1A
GROUND
STUD
NOTE:
Make sure the Liftgate power unit, all batteries on the vehicle for power
unit, and taillights on Liftgate are connected correctly to a common ground.
2.
Extend the ground cable to reach vehicle frame
(FIG. 58-1B)
without putting ten-
sion on cable (after connection). Connect to an existing grounding point if available.
4.
Bolt ground cable terminal lug
(FIG. 58-1A)
to vehicle frame as shown in
FIG. 58-1B
.
3.
If necessary, drill a 11/32” (0.343”) hole in vehicle frame for bolting the ground
cable terminal lug
(FIG. 58-1B)
.
NUT
FIG. 58-1B
TERMINAL LUG
(GROUND CABLE)
5/16” FLAT
WASHER
VEHICLE CHASSIS
(TRUCK FRAME SHOWN)
5/16"-18 X 1" LG.
CAP SCREW
BARE
METAL
1.
Bolt ground cable to the ground stud on pump box
(FIG. 58-1)
.
NOTE:
If there is an existing grounding point on truck frame, use it to connect
ground cable and skip the step for drilling a hole.
LOCK
NUT
FLAT
WASHER
NOTE:
• Before connecting ground cable to frame, clean connection point on the
frame down to bare metal.
• After connecting ground cable,
MAXON
recommends sealing the ground
connection with galvanized coating for galvanized surfaces, or black paint
for painted surfaces.
Summary of Contents for BMR-CS
Page 103: ......