User Manual |
MI-CLARITY3D SA
User Manual |
MI-CLARITY3D
User Manual |
MI-CLARITY3D
©
MASTERIMAGE 3D, Inc.
26
No.
1
st
Level
2
nd
Level
3
rd
Level
4
th
Level
6
AUTOMATION
1. MANUAL
>1
REFERENCE Hz
2. GPIO
OLD: mmm
3. RS-232C
NEW: [MMM]
4. RS-422
[CANCEL] [SAVE]
5. 3D PORT
6. ETHERNET
7. SYNC PULSE
>1
8. EXIT
Select a 3D automation I/O port
Value: MANUAL, GPIO, RS-232C, RS-422, 3D PORT, ETHERNET, SYNC
PULSE | Default: MANUAL
REFERENCE Hz Value: 48 ~ 75Hz |
Default: 72Hz
7
PFD HOME
Set MARK Top,
Setting PFD
PFD Home Setting
and Push [RUN]
Home Position!
Completed!
[CANCEL]
Wait a second…
[EXIT]
Set the PFD Home position to teach the system the 3D synchronization position
for the PFD during the initial installation, after PFD replacement or Factory Default
reset
8
3D PHASE
1. SYNcPOLARITY
>1
>1
SYNC POLARITY
2.OFFSET
>2
OLD: TRUE
3. EXIT
NEW: [INVERT]
[CANCEL] [SAVE]
>2
OFFSET
OLD: mmm
NEW: [MMM]
[CANCEL] [SAVE]
Adjust sync polarity and the offset of 3D phase if any 3D artifacts are seen on
screen
SYNC POLARITY Value: TRUE, INVERT,
Default: TRUE
OFFSET Value: -180 ~ +180 |
Default: +000
9
DIAGNOSTICS
Diagnose
FSMC TEST: mm*
System Status?
EPP TEST: mm
[CANCEL] [OK]
SVO TEST: mm
[EXIT]