5. Check the fuses for continuity.
Open (burned) fuses can be replaced with time delay fuses of either FNM-10 or FNQ-R-10 type.
FNM-10 Type Fuse
6. Install the good fuses and any replacements and close the fuse holders and base door.
7. Plug in the MI-CLARITY3D and turn on the power breaker.
If fuses blow again or if the fuses are OK and therefore not the problem, then contact your local
service provider or MASTERIMAGE Technical Support (see Section 1.2.
11.3.
Servopak Correct Status Indication
The Servopak inside the MI-CLARITY3D has a 7 segment LED display that indicates different
status conditions for the system. Both correct running conditions and error status indications are
described below.
The images below indicate the correct status indication from the Servopak for both Standby and
Running conditions.