DMX address DIP-switch settings

Find the DMX address you want to set in the following table. Read the 
settings for pins 1 - 5 to the left and read the settings for pins 6 - 9 above 
the address. “0” means OFF and “1” means ON. Pin 10 is always OFF for 
DMX operation.

For example, to set a DMX address to 101, set pins 1, 3, 6 and 7 to ON, 
and the other pins to OFF.

 

DIP-Switch Setting

0 = OFF

1 = ON

#9

0

0

0

0

0

0

0

0

1

1

1

1

1

1

1

1

#8

0

0

0

0

1

1

1

1

0

0

0

0

1

1

1

1

#7

0

0

1

1

0

0

1

1

0

0

1

1

0

0

1

1

#6

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

#1 #2 #3 #4 #5

0

0

0

0

0

32 64 96 128 160 192 224 256 288 320 352 384 416 448 480

1

0

0

0

0

1

33 65 97 129 161 193 225 257 289 321 353 385 417 449 481

0

1

0

0

0

2

34 66 98 130 162 194 226 258 290 322 354 386 418 450 482

1

1

0

0

0

3

35 67 99 131 163 195 227 259 291 323 355 387 419 451 483

0

0

1

0

0

4

36 68 100 132 164 196 228 260 292 324 356 388 420 452 484

1

0

1

0

0

5

37 69

101

133 165 197 229 261 293 325 357 389 421 453 485

0

1

1

0

0

6

38 70 102 134 166 198 230 262 294 326 358 390 422 454 486

1

1

1

0

0

7

39 71 103 135 167 199 231 263 295 327 359 391 423 455 487

0

0

0

1

0

8

40 72 104 136 168 200 232 264 296 328 360 392 424 456 488

1

0

0

1

0

9

41 73 105 137 169 201 233 265 297 329 361 393 425 457 489

0

1

0

1

0

10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490

1

1

0

1

0

11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491

0

0

1

1

0

12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492

1

0

1

1

0

13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493

0

1

1

1

0

14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494

1

1

1

1

0

15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495

0

0

0

0

1

16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496

1

0

0

0

1

17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497

0

1

0

0

1

18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498

1

1

0

0

1

19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499

0

0

1

0

1

20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500

1

0

1

0

1

21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501

0

1

1

0

1

22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502

1

1

1

0

1

23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503

0

0

0

1

1

24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504

1

0

0

1

1

25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505

0

1

0

1

1

26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506

1

1

0

1

1

27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507

0

0

1

1

1

28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508

1

0

1

1

1

29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509

0

1

1

1

1

30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510

1

1

1

1

1

31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511

Summary of Contents for Magnum 1500

Page 1: ...Magnum 1500 user manual...

Page 2: ...mensions are in millimeters 2005 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Prof...

Page 3: ...vel 17 Filling the fluid bottle 17 Priming the pump 18 Remote control operation 19 Resetting the thermal cutout 19 Service and maintenance 21 Replacing the main fuse 21 Uploading new software 23 Troub...

Page 4: ...This page intentionally left blank...

Page 5: ...as a separate accessory The most recent version of this manual is available in the Support area of the Martin website at http www martin com F e a t u r e s Onboard 2 3 liter 0 6 US gal 0 5 imperial g...

Page 6: ...attachment eye bolt 2 Mounting bracket 3 Main on off switch 4 AC power input EU model illustrated 5 Fluid bottle release thumbscrews 6 Remote control out 7 Service port 8 Remote control in 9 Fog flui...

Page 7: ...rotection Check the voltage is correct for use with the machine The voltage setting is printed on the machine s serial label Disconnect the machine from AC power before refilling the fluid tank resett...

Page 8: ...up or down from horizontal Preventing injuries due to falls Work from a stable platform and block access below the work area whenever installing servicing or removing the machine Do not hang the mach...

Page 9: ...Magnum 1500 is supplied with the fluid bottle empty to avoid spillage during shipment The fluid bottle must be filled before using for the first time see Filling the fluid bottle on page 17 Your Marti...

Page 10: ...of reach of the public in a location where accidental contact is impossible Do not install the Magnum 1500 at an angle of more than 30 up or down from horizontal To avoid fluid leakage the fluid bottl...

Page 11: ...ough the eye bolt on the housing below the mounting bracket see illustration Do not simply attach the safety wire to the mounting bracket as this will leave the machine unsecured 5 Loosen the swivel l...

Page 12: ...ap remains at the top To reposition the fluid bottle 1 Open the fluid bottle compartment by twisting the two thumbscrews a quarter turn in towards the centre of the machine and pulling the cover off t...

Page 13: ...ndamaged and rated for the current requirements of all connected devices before use Check the power supply setting before applying power Installing a plug on the power cable The power cable must be fi...

Page 14: ...t on the connections plate see illustration 3 When you power the machine on again check that the HEAT indicator on the remote control is lit to show that the machine is warming up Multiple linking wit...

Page 15: ...warranty To link Magnum 1500s 1 Power off all machines 2 Connect the remote control unit to the IN socket on the first Magnum 1500 on the link 3 Lead a suitable cable from the OUT socket on the first...

Page 16: ...on off switch The HEAT indicator LED on the remote control will light and the LED on the machine close to the remote control sockets will light red to indicate pre heating The machine should be ready...

Page 17: ...cover must be opened and the bottle removed to check the fluid level F i l l i n g t h e f l u i d b o t t l e Warning Always disconnect the machine from power before working with the fluid system The...

Page 18: ...e back into its compartment being careful not to trap or kink the fluid hose 7 Replace the compartment cover before reapplying power P r i m i n g t h e p u m p The pump must be primed when the Magnum...

Page 19: ...when the heating element is active It should light continuously during pre heating light occasionally during operation and light continuously during re heating Note that the Magnum 1500 is not designe...

Page 20: ...turn the machine over so that it is resting on its mounting bracket 3 Remove the four T20 Torx screws in the rubber feet and slide the baseplate away from the nozzle end of the machine to give access...

Page 21: ...ay fuse for protection against current overload An indication that the fuse may have blown is that the indicator LEDS do not light if power is applied when the machine is correctly connected to power...

Page 22: ...machine as illustrated to release the side cover on that side of the machine 4 Slide the side cover completely off the machine to give access to the control circuit board 5 The main fuse is located in...

Page 23: ...ssembly is the reverse of the disassembly procedure Be careful not to trap any wires when replacing covers Do not reapply power until all covers and screws are in place and secure If the fuse blows re...

Page 24: ...onnections module No power Check power supply on off switch and connections Control device not connected Check connections Fog disperses too quickly Wrong grade of fluid used for the application Consu...

Page 25: ...ubleshooting aids If the Magnum 1500 flashes a service code reset the machine by powering off and on again If the code persists refer to your Martin dealer Service code Message One short blink every s...

Page 26: ...ains 5 m 16 4 ft of ducting I n s t a l l i n g a d u c t i n g a d a p t e r Warning Airflow is necessary at the entrance to the ducting Never block the air gap between the Magnum 1500 and the ductin...

Page 27: ...t long More devices can be added and the link can be extended beyond 500 meters or branched using an optically isolated splitter amplifier such as the Martin RS 485 Opto Splitter P N 90758060 D M X i...

Page 28: ...e connected to the 3 pin male connector on the circuit board not the 6 pin connector used by the remote control module see illustration 5 Hold the DMX module up to the housing and push the DMX interfa...

Page 29: ...supply suitable high quality cable in various lengths The Magnum 1500 s XLR data sockets are wired with pin 1 to ground pin 2 to signal cold and pin 3 to signal hot This is the standard pin assignmen...

Page 30: ...pecifying DMX control addresses The Magnum 1500 uses a single DMX control channel to receive instructions from the controller This control channel is the Magnum 1500 s DMX address The DMX address must...

Page 31: ...wn in the illustration below 3 Power off the controller and all the machines you want to connect to the DMX link 4 For each machine set the DMX address by setting the DIP switch pins 1 through 9 to th...

Page 32: ...426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301...

Page 33: ...eceived and the machine starts to warm up The Magnum 1500 is ready for operation after approximately 10 minutes Set the level on the Magnum 1500 s DMX control channel to zero to cut fog output to zero...

Page 34: ...capacity 2 3 liters 4 0 Imp pints 4 9 US pints Maximum fluid consumption 80 ml 0 14 Imp pints 0 17 US pints per minute 64 ml 0 11 Imp pints 0 14 US pints per max run time 48 secs Thermal Maximum ambi...

Page 35: ...tems US model 2 m 6 5 ft US power cable 18AWG with US male connector UL approved User manual P N 35000160 Remote control with 5 m 16 4 ft cable and RJ 45 connector P N 62020071 A c ce s s o ri es JEM...

Page 36: ...Martin Professional A S Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Internet www martin com...

Reviews: