background image

30

Magnum 1500 user manual

To connect a 5-pin XLR output to the Magnum 1500, use a 5-pin male to 
3-pin female XLR adaptor cable (P/N 11820005). To connect the Magnum 
1500 to a 5-pin XLR input, use a 3-pin male to 5-pin female adaptor cable 
(P/N 1820004). To connect to devices with reversed polarity, use a phase-
reversing adaptor (P/N 1820006)

To connect a DMX data link:

1. Power off all devices. 
2. Using suitable data cable, connect the controller’s DMX output to the 

first device’s DMX input.

3. Connect the DMX output of the first device to the DMX input of the next 

device.

4. Continue connecting devices output to input. 
5. Terminate the link by inserting a male termination plug (available from 

your Martin dealer: P/N 91613017) into the DMX output of the last 
device. A termination plug is simply an XLR connector with a 120 Ohm, 
0.25 W resistor soldered across pins 2 and 3.

Specifying DMX control addresses

The Magnum 1500 uses a single DMX control channel to receive 
instructions from the controller. This control channel is the Magnum 1500’s 
DMX address. The DMX address must be set on the Magnum 1500 for 
instructions to be received successfully on this channel from the controller.

To control devices individually, each must have its own unique DMX 
address. To control devices as a group, they can all be given the same 
DMX address. They will then receive the same instructions and should 
behave identically. Setting up identical devices with the same DMX 
address can also be a good tool for troubleshooting unexpected behavior.

A Magnum 1500’s DMX address can be set to any channel from 1 to 511 
using DIP-switches 1 - 9 on the DMX module.

To set the DMX address:

1. Choose an available address for the Magnum 1500.
2. Look up the DIP-switch settings for this address using the Martin 

Address Calculator at 
http://www.martin.dk/service/utilities/AddrCalc/index.asp or look for the 
address in the DIP-switch settings table on page 32. For example, to 

Summary of Contents for Magnum 1500

Page 1: ...Magnum 1500 user manual...

Page 2: ...mensions are in millimeters 2005 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Prof...

Page 3: ...vel 17 Filling the fluid bottle 17 Priming the pump 18 Remote control operation 19 Resetting the thermal cutout 19 Service and maintenance 21 Replacing the main fuse 21 Uploading new software 23 Troub...

Page 4: ...This page intentionally left blank...

Page 5: ...as a separate accessory The most recent version of this manual is available in the Support area of the Martin website at http www martin com F e a t u r e s Onboard 2 3 liter 0 6 US gal 0 5 imperial g...

Page 6: ...attachment eye bolt 2 Mounting bracket 3 Main on off switch 4 AC power input EU model illustrated 5 Fluid bottle release thumbscrews 6 Remote control out 7 Service port 8 Remote control in 9 Fog flui...

Page 7: ...rotection Check the voltage is correct for use with the machine The voltage setting is printed on the machine s serial label Disconnect the machine from AC power before refilling the fluid tank resett...

Page 8: ...up or down from horizontal Preventing injuries due to falls Work from a stable platform and block access below the work area whenever installing servicing or removing the machine Do not hang the mach...

Page 9: ...Magnum 1500 is supplied with the fluid bottle empty to avoid spillage during shipment The fluid bottle must be filled before using for the first time see Filling the fluid bottle on page 17 Your Marti...

Page 10: ...of reach of the public in a location where accidental contact is impossible Do not install the Magnum 1500 at an angle of more than 30 up or down from horizontal To avoid fluid leakage the fluid bottl...

Page 11: ...ough the eye bolt on the housing below the mounting bracket see illustration Do not simply attach the safety wire to the mounting bracket as this will leave the machine unsecured 5 Loosen the swivel l...

Page 12: ...ap remains at the top To reposition the fluid bottle 1 Open the fluid bottle compartment by twisting the two thumbscrews a quarter turn in towards the centre of the machine and pulling the cover off t...

Page 13: ...ndamaged and rated for the current requirements of all connected devices before use Check the power supply setting before applying power Installing a plug on the power cable The power cable must be fi...

Page 14: ...t on the connections plate see illustration 3 When you power the machine on again check that the HEAT indicator on the remote control is lit to show that the machine is warming up Multiple linking wit...

Page 15: ...warranty To link Magnum 1500s 1 Power off all machines 2 Connect the remote control unit to the IN socket on the first Magnum 1500 on the link 3 Lead a suitable cable from the OUT socket on the first...

Page 16: ...on off switch The HEAT indicator LED on the remote control will light and the LED on the machine close to the remote control sockets will light red to indicate pre heating The machine should be ready...

Page 17: ...cover must be opened and the bottle removed to check the fluid level F i l l i n g t h e f l u i d b o t t l e Warning Always disconnect the machine from power before working with the fluid system The...

Page 18: ...e back into its compartment being careful not to trap or kink the fluid hose 7 Replace the compartment cover before reapplying power P r i m i n g t h e p u m p The pump must be primed when the Magnum...

Page 19: ...when the heating element is active It should light continuously during pre heating light occasionally during operation and light continuously during re heating Note that the Magnum 1500 is not designe...

Page 20: ...turn the machine over so that it is resting on its mounting bracket 3 Remove the four T20 Torx screws in the rubber feet and slide the baseplate away from the nozzle end of the machine to give access...

Page 21: ...ay fuse for protection against current overload An indication that the fuse may have blown is that the indicator LEDS do not light if power is applied when the machine is correctly connected to power...

Page 22: ...machine as illustrated to release the side cover on that side of the machine 4 Slide the side cover completely off the machine to give access to the control circuit board 5 The main fuse is located in...

Page 23: ...ssembly is the reverse of the disassembly procedure Be careful not to trap any wires when replacing covers Do not reapply power until all covers and screws are in place and secure If the fuse blows re...

Page 24: ...onnections module No power Check power supply on off switch and connections Control device not connected Check connections Fog disperses too quickly Wrong grade of fluid used for the application Consu...

Page 25: ...ubleshooting aids If the Magnum 1500 flashes a service code reset the machine by powering off and on again If the code persists refer to your Martin dealer Service code Message One short blink every s...

Page 26: ...ains 5 m 16 4 ft of ducting I n s t a l l i n g a d u c t i n g a d a p t e r Warning Airflow is necessary at the entrance to the ducting Never block the air gap between the Magnum 1500 and the ductin...

Page 27: ...t long More devices can be added and the link can be extended beyond 500 meters or branched using an optically isolated splitter amplifier such as the Martin RS 485 Opto Splitter P N 90758060 D M X i...

Page 28: ...e connected to the 3 pin male connector on the circuit board not the 6 pin connector used by the remote control module see illustration 5 Hold the DMX module up to the housing and push the DMX interfa...

Page 29: ...supply suitable high quality cable in various lengths The Magnum 1500 s XLR data sockets are wired with pin 1 to ground pin 2 to signal cold and pin 3 to signal hot This is the standard pin assignmen...

Page 30: ...pecifying DMX control addresses The Magnum 1500 uses a single DMX control channel to receive instructions from the controller This control channel is the Magnum 1500 s DMX address The DMX address must...

Page 31: ...wn in the illustration below 3 Power off the controller and all the machines you want to connect to the DMX link 4 For each machine set the DMX address by setting the DIP switch pins 1 through 9 to th...

Page 32: ...426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301...

Page 33: ...eceived and the machine starts to warm up The Magnum 1500 is ready for operation after approximately 10 minutes Set the level on the Magnum 1500 s DMX control channel to zero to cut fog output to zero...

Page 34: ...capacity 2 3 liters 4 0 Imp pints 4 9 US pints Maximum fluid consumption 80 ml 0 14 Imp pints 0 17 US pints per minute 64 ml 0 11 Imp pints 0 14 US pints per max run time 48 secs Thermal Maximum ambi...

Page 35: ...tems US model 2 m 6 5 ft US power cable 18AWG with US male connector UL approved User manual P N 35000160 Remote control with 5 m 16 4 ft cable and RJ 45 connector P N 62020071 A c ce s s o ri es JEM...

Page 36: ...Martin Professional A S Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Internet www martin com...

Reviews: