3. Slide the fluid bottle out of
the compartment and
remove the cap with
attached fluid suction hose
from the bottle.
4. Fill the bottle with Martin or
JEM Pro Smoke Fluid (ZR
mix) or Regular DJ Fluid
(DJ mix) only.
5. Check that the filter on the
end of the fluid suction
hose is clean and replace
the cap tightly, ensuring
that the hose reaches the
bottom of the bottle.
6. Slide the fluid bottle back into its compartment, being careful not to trap
or kink the fluid hose.
7. Replace the compartment cover before reapplying power.
P r i m i n g t h e p u m p
The pump must be primed when the Magnum 1500 is used for the first
time, or if it has not been used for an extended period.
To prime the pump:
1. Check that the fluid bottle is full. Power the machine on and allow it to
reach operating temperature.
2. If using the remote control, set the TIMER on the remote control to
zero, set LEVEL to maximum and press the FOG button for 10 - 15
seconds.
3. If using DMX, set the machine to maximum fog output for 10 - 15
seconds.