20
Magnum 1500 user manual
If this occurs, you will need to manually reset the thermal cutout. To do
this:
1. Isolate the machine from power by disconnecting the power cable and
allow the machine to cool for at least 20 minutes.
2. If the machine is resting on its rubber feet, remove the fluid
compartment cover, remove the fluid bottle and turn the machine over
so that it is resting on its mounting bracket.
3. Remove the four T20 Torx screws in the rubber feet and slide the
baseplate away from the nozzle end of the machine to give access to
the reset switch cover.
4. Remove the four T20 Torx screws from the reset switch cover and lift
the cover off the machine..
5. Press the plastic reset switch to reset the thermal protection cutout.
6. Replace all covers and screws before reapplying power.
If the thermal cutout operates repeatedly, contact your Martin dealer for
service.