–129–
EC50 SELF-CONTAINED AIR-COOLED — LARGE CUBE
NOTE:
These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Continued on next page …
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times
in
minutes.
Water Temperature °C
10
15
20
25
30
35
40
10
24.8-26.7
3.5 min.
15
26.8-28.7
27.8-29.8
20
29.0-31.1
30.2-32.4
31.5-33.8
32.2-34.5
33.7-36.1
25
31.5-33.8
32.9-35.3
33.7-36.1
35.3-37.8
37.1-39.7
30
34.5-36.9
36.2-38.7
37.1-39.7
39.0-41.8
41.1-44.0
43.5-46.5
46.1-49.3
35
41.1-44.0
43.5-46.5
46.1-49.3
49.0-52.4
52.3-55.9
40
52.3-55.9
56.0-59.9
60.3-64.4
45
60.3-64.4
65.2-69.6
70.9-75.7
Summary of Contents for EC18