–92–
EC18 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10
6.55-4.48
1.10-0.14
3.10-4.14
2.07-3.10
20
9.31-6.89
1.24-0.28
4.48-5.52
3.10-4.14
25
10.69-7.24
1.38-0.34
4.83-6.55
3.79-4.48
32
13.10-9.31
1.72-0.55
6.20-8.27
5.17-5.86
43
17.24-12.07
1.72-0.69
7.58-10.69
6.21-7.58