Part Number 80-1479-3 10/10
WATER INLET VALVE WON’T ENERGIZE
No Timer
1. Line voltage at water inlet valve? (Wires 21 & 22)
Yes - Replace water inlet valve coil.
No - Refer to evaporator thermostat diagnostics.
(22)
HOT GAS
SOLENOID
WATER INLET
SOLENOID
EVAP THERMOSTAT
(21)
(7)
(10)
(6)
C
H
L
(3)
1