–152–
EC80 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10
13.79-9.65
3.45-1.52
6.89-8.27
4.48-5.17
20
17.24-12.41
4.14-1.93
9.31-11.03
6.21-7.24
25
17.24-13.79
4.48-2.07
10.68-12.41
6.89-7.93
32
21.37-17.24
4.69-2.27
12.07-15.17
8.27-10.00
43
26.20-21.37
5.17-2.48
16.55-17.24
9.65-11.72