–116–
EC40 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10
7.58-4.48
1.72-.14
2.41-4.14
1.38-2.07
20
11.03-5.86
1.94-.28
3.45-5.87
1.72-3.45
25
13.10-7.24
1.94-.34
3.79-6.55
2.07-4.14
32
15.86-9.31
1.94-.41
4.82-8.27
2.76-4.82
43
21.37-11.72
2.34-.48
5.17-11.72
3.45-7.93