–128–
EC50 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10
9.31-4.48
2.76-.14
2.76-4.83
1.38-2.76
20
14.48-6.21
3.31-.14
4.14-7.58
1.72-4.48
25
14.48-7.58
3.45-.14
4.82-8.27
2.07-4.82
32
17.23-8.96
3.79-.14
6.21-9.65
2.76-5.87
43
24.13-12.07
4.27-.21
7.93-12.76
3.45-7.93