Part Number 80-1479-3 10/10
69
LOW AMBIENT ADJUSTMENT FOR MECHANICAL
TIMER
Timer adjustment for operation in temperatures below
10°C.
1. Disconnect power to the ice machine.
2. Remove timer adjustment tool from the inside of the
control box cover.
3. Adjust harvest time to 5 minutes (easier access can
be obtained by removing the timer mounting
screws).
4. One time adjustment, the timer does not need to be
readjusted for summer/winter operation.