46
Part Number 80-1479-3 10/10
SCR Timer Models
WATER PUMP WON’T RUN
SCR Timer
1. Toggle switch terminals 2 & 1 closed?
(wires #64 & #3)
2. Timer relay closed?
(wires #3 & #5 - contacts C & NC on timer)
3. Water pump winding closed?
NC
C
NO
6
2
TIME DELAY
RELAY
1
RELAY
WATER
PUMP
TOGGLE SWITCH
3
1
2
6
4
5
(8)
(5)
(33)
(3)
(49)
(65)
(64)
1
2
3