–81–
Contamination/Cleanup Chart
Symptoms/Findings
Required Cleanup
Procedure
No symptoms or suspicion of
contamination.
Normal evacuation/
recharging procedure
Moisture/Air Contamination
symptoms. Refrigeration
system open to atmosphere for
longer than 15 minutes.
Refrigeration test kit and/or acid
oil test shows contamination.
No burnout deposits in open
compressor lines.
Mild contamination
cleanup procedure
Mild Compressor Burnout
symptoms. Oil appears clean
but smells acrid. Refrigeration
test kit or acid oil test shows
harmful acid content. No
burnout deposits in open
compressor lines.
Mild contamination
cleanup procedure
Severe Compressor Burnout
symptoms. Oil is discolored,
acidic, and smells acrid.
Burnout deposits found in the
compressor, lines, and other
components.
Severe contamination
cleanup procedure
Summary of Contents for EC18
Page 2: ......
Page 6: ...This Page Intentionally Left Blank ...
Page 12: ...This Page Intentionally Left Blank ...
Page 14: ... 2 This Page Intentionally Left Blank ...
Page 24: ...12 Part Number 80 1479 3 10 10 Evaporator Ice Chute Spray Bar Spray Nozzles Toggle Switch ...
Page 42: ...30 Part Number 80 1479 3 10 10 This Page Intentionally Left Blank ...
Page 74: ...62 Part Number 80 1479 3 10 10 This Page Intentionally Left Blank ...
Page 75: ...Part Number 80 1479 3 10 10 63 ...
Page 100: ... 87 This Page Intentionally Left Blank ...
Page 101: ... 88 This Page Intentionally Left Blank ...
Page 175: ... 162 This Page Intentionally Left Blank ...
Page 181: ... 168 ...
Page 182: ......
Page 183: ......