6.3.1 Safe working when connecting the water supply and the drain
For your safety
Before starting work, familiarize yourself with the hazards described in '
tions during installation on page 30'.
Eligibility of personnel connecting the water supply and the wastewater system
Only qualified plumbers from an authorized service company are permitted to connect the combi
steamer to the water supply and to the waste wastewater system.
Personal protective equipment
Wear the personal protective equipment specified in the section '
Personal protective equipment on
page 43' of the 'For your safety' chapter for the relevant tasks.
Regulations for the water supply
Make sure that you comply with all local and national regulations relating to the water supply. These
include:
DIN 1988 part 2 and part 4
EN 61770
EN 1717
Water installation must be done in compliance with AS/NZS 3500 Plumbing and Drainage Code.
Australia only:
Dual check valve supplied with this appliance must be installed in the water supply line to this appli‐
ance to provide total backflow prevention required by Plumbing Code of Australia.
Regulations for the drain connection
You must comply with local and national regulations on the design of the drain connection and on the
composition of the wastewater. These include:
DIN 1988 part 2 and part 4
DIN EN 1717
Local wastewater regulations
6 Installation
Installation manual
87