Height requirement
The following diagram and table show the vertical space needed by the appliance:
H1
H2
H1
The service engineer who is responsible for setting up the appliance must take into account the nature
of the ceiling and any adjacent systems that may be used (air conditioning system, vapour extractor
hood etc.) when designing the particular clearance needed between the top of the appliance and the
ceiling. In this context, the vertical distance H1 must be understood as a guide value for the minimum
vertical clearance.
Meaning
6.10
6.20
10.10
10.20
12.20 20.10 20.20
Electric appliances
H1 Guide value for
the minimum ver‐
tical clearance
[mm] 500
500
500
500
500
500
500
Gas appliances
H1 Guide value for
the minimum ver‐
tical clearance
[mm] 1000
1000
1000
1000
1000 1000 1000
Electric appliances and gas
appliances
H2 Installation height [mm] 620 - 900 620 - 900 620 - 900 620 - 900 -
-
-
5 Setting up the appliance
Installation manual