16.4.1.3
Function and adjustment of the time delay relay K1
After the back purge action, the time relay
K1
(EZ12AV) finishes the message „Back purge“ with
a time delay of eg. 1 min and releases the measurement again in order to have sample gas in
the analyzers when you switch over from back purging to measuring.
In the front of the time relay, the switches for the time basis T and the multiplicator xT are
situated.
Example:
Delay time: 1 min.
Adjust the time basis T to 1 min. and the multiplicator xT to 1 (1 x 1 min. = 1 min).
16.4.1.4
Function for ball valve position NC „normally closed“
After actuation of the back purge action by
K3
(type CT-MXS.22), the message purging is given via the time relay
K1
(EZ12AV), the control solenoid valve
Y1
(see figure 15 and 16) is closed and the ball valve returns in its rest
position by spring return (back purge).
The clock relay
K2
(type EZ12TI) is piloted for eg. 10 s and switches on and off again the back purge solenoid valve
Y2
in a clock cycle of eg. 1 s.
After this, it is pause time in which the solenoid valve
Y1
is changed over again to the measuring gas sampling. At
the same time, the time-delay relay is switched which – after a delay time of eg. 1 min. - finishes the message
„purging“ and releases again the measurement. This delay time is necessary in order to have active sample gas in
the analyzers during switching over from purging to measuring.
16.4.1.5
Function for ball valve position NO „normally open“
After actuatig the back purge action through
K3
(type CT-MXS.22), the message „purging“ appears via the time
relay
K1
(EZ12.AV), the control solenoid valve
Y1
(see figure 15 and 16) is opened and the pneumatic drive moves
the ball valve into position „back purging“.
The clock relay
K2
(type EZ12.TI) is triggered for eg. 10 s by
K3
and switches on and off again the back purge sole-
noid valve
Y2
in intervals of eg. 1 s.
After this, it is pause time in which the solenoid valve
Y1
is changed over again to the measuring gas sampling. At
the same time, the time-delay relay is switched which – after a delay time of eg. 1 min. – finishes the message
„purging“ and releases again the measurement. This delay time is necessary in order to have active sample gas in
the analyzers during switching over from purging to measuring.
Summary of Contents for SP Series
Page 48: ...48 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 24 SP2000 H basic version ...
Page 49: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 49 Figure 25 SP2000 H with options ...
Page 50: ...50 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 26 SP2300 H ...
Page 51: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 51 Figure 27 SP2300 H filter elements ...
Page 53: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 53 Figure 29 Heated sample tubes SP30 H ...
Page 54: ...54 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com ...
Page 56: ...56 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 31 SP2000 H 3VA MS NC B ...
Page 57: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 57 Figure 32 SP2000 H 3VA MS NC C ...
Page 58: ...58 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 33 SP2000 H 3VA MS NO B ...
Page 59: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 59 Figure 34 SP2000 H 3VA MS NO C ...