www.mc-techgroup.com SP2000,
SP2300, SP2400 | 1.00.03
27
Insert the temperature sensor cable through the right cable gland M20 x 1.5 and connect to the appropriate
terminals.
Screw lid back on.
Note
In case of versions with thermoelement (e.g. with option -H320/C) a compensation wire is to
be provided as sensor line. Corresponding balancing terminals are provided in the connec-
tion box.
Figure 10
Electrical connection of external temperature controller e.g. 70304G
The electrical connection of the temperature regulator
70304G
is effected according to the connection plan (figure
11) and as described in the following:
Unscrew and remove the housing lid.
Introduce the mains cable (min. 3 x 1.5 mm
2
, clamping range 6 – 12 mm) through the left cable gland M20
x
1.5 of the regulator and connect it to the respective terminals.
Introduce the cable for the alarm contact (clamping range 6 - 12mm) through the right cable gland M20 x 1.5
and connect it to the repective terminals.
In case the temperature regulator
70304G
is attached as separate unit, the probe has additionally to be connected
with the regulator, according to figure 10 and the following description:
Introduce the power cable for the sample gas probe (min. 3 x 1,5 mm
2
, clamping range 6 – 12 mm) through the
second cable gland M20 x 1.5 of the regulator and connect it to the respective terminals.
Introduce the temperature sensor cable (clamping range 6 – 12 mm) through the third cable gland M20 x 1.5
of the regulator and connect it to the respective terminals.
Screw the lid on the housing again.
Summary of Contents for SP Series
Page 48: ...48 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 24 SP2000 H basic version ...
Page 49: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 49 Figure 25 SP2000 H with options ...
Page 50: ...50 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 26 SP2300 H ...
Page 51: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 51 Figure 27 SP2300 H filter elements ...
Page 53: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 53 Figure 29 Heated sample tubes SP30 H ...
Page 54: ...54 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com ...
Page 56: ...56 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 31 SP2000 H 3VA MS NC B ...
Page 57: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 57 Figure 32 SP2000 H 3VA MS NC C ...
Page 58: ...58 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 33 SP2000 H 3VA MS NO B ...
Page 59: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 59 Figure 34 SP2000 H 3VA MS NO C ...