www.mc-techgroup.com SP2000,
SP2300, SP2400 | 1.00.03
13
11
PROBE DESIGN OF THE HEATED VERSION
A complete gas sample probe consists of the heated filter part and a sample tube or prefilter. The filter housing
with its all-round heating element
forms a unit with the standard mounting flange DN 65 PN 6
and the laterally
mounted electrical connection box
.
The heat-insulated shield is mounted on the stainless steel angle
sheet which is mounted on the mounting
flange. It is secured with 2 pressure clamps. The cover ensures a uniform distribution of heat over the probe heater
and at the same time serves as protection against weather and accidental contact.
Figure 1
Design of basic version SP2000-H
11.1
SAMPLE GAS CONNECTION
The connecting clamp
for attaching heated
M&C
sample lines with external dimensions of between 40 and max.
50 mm is located at the aperture on the underside of the angle sheet, which is closed with a silicon lid
. The clamp
is mounted on an adjustable mounting bracket which allows adjustment for various sample line diameters.
The standard probe's sample gas outlet connection has a ¼" NPT internal thread to which the customer must con-
nect a suitable size of temperature resistant and threaded connector to connect the sample line in a gas tight
manner. These connectors can be supplied by
M&C
.
In the high-temperature version
-H320/C...
, the sample gas outlet connection is fitted with a welded 6 mm
threaded pipe connection (optional 8 mm).
After the threaded pipe connector and sample line have been mounted, the sample gas outlet connection is en-
closed in special heat-conducting jaws
in order to avoid temperature failures in the critical connection areas. The
size of the heat-conducting jaws allows connection joints up to an external pipe dimension of 10 mm.
Summary of Contents for SP Series
Page 48: ...48 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 24 SP2000 H basic version ...
Page 49: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 49 Figure 25 SP2000 H with options ...
Page 50: ...50 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 26 SP2300 H ...
Page 51: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 51 Figure 27 SP2300 H filter elements ...
Page 53: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 53 Figure 29 Heated sample tubes SP30 H ...
Page 54: ...54 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com ...
Page 56: ...56 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 31 SP2000 H 3VA MS NC B ...
Page 57: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 57 Figure 32 SP2000 H 3VA MS NC C ...
Page 58: ...58 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 33 SP2000 H 3VA MS NO B ...
Page 59: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 59 Figure 34 SP2000 H 3VA MS NO C ...