297
P068A - Main relay early opening error
P068B - Main relay struck error
COMPONENT LOCATION
NORMAL
OPERATION
EMS ECU checks the main relay actuation time during initialization and is within
the range
ECU checks the main relay during operation and no sticky operation noticed
DTC DETECTING
CONDITION
The main relay is not operating in the set time
PROBABLE
CAUSES
Open /short wiring harness
Loosen wiring harness connectors
Sticky relay
Faulty BEC
LAMP STATUS
No lamp indication
DTC REACTION
Engine will not start
No communication from EMS
HEALING
CONDITION
Ignition OFF/ON
Note-
This DTC's will be viewed in the diagnostic tool in healed condition only