282
P0651 - Sensor supply voltage 2 monitoring error
SENSOR SUPPLY VOLTAGE MONITORING
EMS ECU monitors the reference voltage of the critical sensors and registers a DTC if the voltage is not
within the range
NORMAL
OPERATION
EMS ECU monitors the reference supply voltage to APP2 and are within the
range
DTC DETECTING
CONDITION
The sensor supply voltage to the APP2 is out of the range
PROBABLE
CAUSES
Short in sensor supply wire
Faulty APP2 sensor
LAMP STATUS
System check lamp ON
DTC REACTION
Torque limitation
HEALING
CONDITION
Ignition OFF/ON
CIRCUIT SCHEMATIC