P1C88 -
Rail pressure above maximum limit error in Metering Unit mode
NORMAL
OPERATION
The ECU compares the rail pressure monitored through the rail pressure sensor
against the expected pressure generated due to HPP ( Based on MPROP
position and the engine RPM and coolant temperature )
DTC DETECTING
CONDITION
Rail pressure exceeds above the limiting value
PROBABLE
CAUSES
M prop valve struck
Zero delivery throttle clogged
Metering unit without power due to electrical error
LAMP STATUS
System check lamp ON
DTC REACTION
Engine shuts off
HEALING
CONDITION
Ignition OFF/ON