![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624080.webp)
Open-loop Power Data D2
80
FLUX CURRENT
(Flux Current)
Displays the flux producing current of the motor.
TORQUE CURRENT
(Torque Current)
Displays the torque producing current of the
motor.
FLUX VOLTAGE
(Flux Voltage)
Displays the flux voltage reference.
TORQUE VOLTAGE
(Torque Voltage)
Displays the torque voltage reference.
BASE IMPEDANCE
(Base Impedance)
Displays the drive calculated base impedance,
which is based on the RATED MTR PWR (A5)
and the RATED MTR VOLTS (A5) parameters.
This value is used to calculate the Per Unit
values of the system impedances (i.e. EXTERN
REACTANCE (A4) and STATOR RESIST(A5)).
EST STATOR RESIST
(Estimated Stator Resistance)
Approximate estimate of the motor’s stator
resistance (do not use for tuning drive)