Closed-loop Analog Outputs C4
121
Configure C0 menu
Analog Outputs C4 submenu
C4
parameter
description
default
hidden
item
run
lock
out
ANALOG OUTPUT 1
analog output #1
TORQUE REF
N
Y
ANALOG OUTPUT 2
analog output #2
SPEED FEEDBK
N
Y
choices
aux torq cmd
Additional torque command from auxiliary source
bus voltage
Measured DC bus voltage
current out
Percent motor current
drv overload
Percent of drive overload trip level reached
flux current
Measured flux producing current
flux output
Measured flux output
flux ref
Flux reference used by vector control
flux voltage
Flux producing voltage
frequency
out
Electrical
frequency
mtr overload
Percent of motor overload trip level reached
power output
Calculated power output
pretorque ref
Pre-torque reference
slip freq
Commanded slip frequency
spd rg tq cmd
Torque command from speed regulator
speed command
Speed command before S-Curve
speed error
Speed reference minus speed feedback
speed feedbk
Speed feedback used by speed regulator
speed ref
Speed reference after S-Curve
tach rate cmd
Torque command from tach rate gain function
torq current
Measured torque producing current
torq voltage
Torque producing voltage
torque output
Calculated torque output
torque ref
Torque reference used by vector control
voltage out
RMS motor terminal voltage
Detailed description
ANALOG OUTPUT 1
(Analog Outputs 1)
Default: TORQUE REF
This parameter defines the function of the
analog output #1.
NOTE: The
current
setting of each parameter is
displayed in all caps; all other choices in the list
are displayed in lower case.
ANALOG OUTPUT 2
(Analog Outputs 2)
Default: SPEED FEEDBK
This parameter defines the function of the
analog output #2.
NOTE: The
current
setting of each parameter is
displayed in all caps; all other choices in the list
are displayed in lower case.