Open-loop Drive A1
46
A1
parameter
description
default
units
min
max
hidden
item
run
lock
out
UP/DWN THRESHOLD
Threshold for
detection of up or
down direction
1.00 %
contract
speed
0.00 9.99
N
Y
MTR TORQUE LIMIT
Motoring current limit
as a percent of the
drive’s rated current
200.0 %
rated
torque
0.0 275.0 N
N
REGEN TORQ LIMIT
Regenerating current
limit as a percent of
the drive’s rated
current
200.0 %
rated
torque
0.0 275.0 N
N
ANA 1 OUT OFFSET
Subtracts an effective
voltage to actual
analog output 1
0.00 %
-99.9
99.9
N
Y
ANA 2 OUT OFFSET
Subtracts an effective
voltage to actual
analog output 2
0.00 %
-99.9
99.9
N
Y
ANA 1 OUT GAIN
Scaling factor for
analog output 1
1.0 none 0.0
10.0 N
Y
ANA 2 OUT GAIN
Scaling factor for
analog output 2
1.0 none 0.0
10.0 N
Y
FLT RESET DELAY
Time before a fault is
automatically reset
5 seconds
0
120 N N
FLT RESETS / HOUR
Number of faults that
is allowed to be
automatically reset
per hour
3 faults
0
10 N N
UP TO SPD. LEVEL
Threshold for up to
spd logic output
80.00 %
contract
speed
0.00 110.00 N
N
TRQ LIM MSG DLY
Delay Torque Limit
Hit message for this
time.
0.50 seconds
0.00
10.00 N
Y
ENCODER PULSES
Only used for
diagnostics…
Encoder counts per
revolution for use only
by ENCODER
SPEED (D1) display
1024 none 600 10000 N
Y